Digital displays for work safety
Operating instructions
Страница 1: ...Series XC610 Digital displays for work safety Operating instructions ...
Страница 2: ...Cleaning 5 Accuracy of the display 5 3 Important start up instructions 6 4 Product description 7 5 Installation 8 Requirements to the installation site 8 Installation material 8 Disassembly of the fastening elements 8 Mounting the unit 8 Power supply connection 9 6 Connecting the configuration interface 10 Configuration via serial interface RS232 10 Configuration via Ethernet 10 7 Start up and con...
Страница 3: ... or serious bodily harm CAUTION Disregarding the warning notice can lead to minor physical injuries or property damage Intended use The unit is intended for use in photovoltaic systems It may only be operated within the limit values stipulated by the technical data During configuring installing testing commissioning and maintenance of the unit the applicable standards and safety regulations have t...
Страница 4: ...eliable mounting The user must ensure that the used fixing material guarantees under the given surrounding conditions a secure mounting When installing and commissioning please note the appropriate national and regional regulations Transport The unit must be transported clean and dry in the original packing The transport temperature must be between 40 C and 70 C Temperature fluctuations of more th...
Страница 5: ...ability and technical specifications of the product are subject to change The data specified is indicated solely for product description They are not intended to be guaranteed in a legal sense Cleaning For the care of the front panel use a scratch free cloth Do not push in the front pane during cleaning The unit must not be cleaned with a steam cleaner Accuracy of the display If the digital displa...
Страница 6: ... have ready the following items A cross type cable for the RS232 interface between the PC and the display If your PC does not have such an interface you need an USB on RS232 converter Siebert offers such a converter together with the matching ready made cable as accessories With displays of the type 05 with Ethernet interface the configuration is done via the Ethernet Please have ready the followi...
Страница 7: ...C610 series are differed in the following interface versions Order code Interfaces XC610 xxx x 01 Serial RS232 screw type terminals XC610 xxx x 05 Ethernet RJ45 The configuration and the modification of the values is effected by the means of the Windows program SafetyDisplayConfigurator included in delivery For installation and connection of the data source you must open the display Thereto loosen...
Страница 8: ... fastening elements are mounted on the front glass Loosen the setscrews with the supplied Allen key and remove the fastening elements Pay particular attention to the plastic panes which serve to protect the glass panels Mounting the unit The lines for data and power supply are fed through the guide holes in the bottom of the housing or at the bottom edge of the device Mount the unit using the moun...
Страница 9: ...upply Therefore there is a jack on the printed circuit board Once the power supply unit is plugged into the 230 V outlet the display should light up When first powered on numbers appear on all digits Depending on the unit version during later power up after implementing of the configuration the decimal points light up ...
Страница 10: ...tching USB adapter You can get this as an accessory from Siebert For normal operation of the display the serial connection is not needed Configuration via Ethernet Devices with the ending number 05 are intended for use in an Ethernet network The connection to a network is limited to plug in the network connector If you connect the device to the network via a switch or a hub then you need an Ethern...
Страница 11: ...completed the configuration the PC is no longer needed Start up and test Expediently perform a functional test before you close the device permanently Controls With the button on the printed circuit board the system can be reset to its basic configuration Turn off the power supply of the display and keep the button pressed while the power supply is turned back on On the printed circuit board there...
Страница 12: ...and the holes for wall mounting Series XC610 Dimensions W x H x D 420 x 297 x 26 mm LED display digit height 25 mm Power supply 100 240 V AC 50 60 Hz Power consumption 25 W max Protection type IP40 Weight approx 2 kg Operating temperature 0 40 C Storage temperature 25 85 C holes for wall mounting 4 5 ...
Страница 13: ...ands Siebert Nederland B V Jadedreef 26 NL 7828 BH Emmen Phone 31 0 591 633444 Fax 31 0 591 633125 info nl siebert solar com Austria Siebert Österreich GmbH Mooslackengasse 17 A 1190 Wien Phone 43 0 1 890 63 86 0 Fax 43 0 1 890 63 86 99 info at siebert solar com Switzerland Siebert AG Bützbergstrasse 2 Postfach 91 CH 4912 Aarwangen Phone 41 0 62 922 20 43 German Phone 41 0 62 922 20 44 French Fax ...