Series S302
Numeric large size displays with PROFINET IO RT interface
Operating instructions
Страница 1: ...Series S302 Numeric large size displays with PROFINET IO RT interface Operating instructions...
Страница 2: ...rl 4 rue de l Abb Louis Verdet F 57200 Sarreguemines P O Box 90 334 F 57203 Sarreguemines C dex Phone 33 0 3 87 98 63 68 Fax 33 0 3 87 98 63 94 email info fr siebert group com ITALY Siebert Italia Srl...
Страница 3: ...ard are registered trademarks of Siebert Industrieelektronik GmbH All other product names mentioned herein may be trademarks or registered trademarks of their respective owners We reserve the right to...
Страница 4: ...OFINET device name to the display 11 Step 7 Download configuration in the controller 11 Step 8 Transmit data to the display 12 6 Quick start for alphanumeric operation mode ASCII format 13 Step 1 to 4...
Страница 5: ...n normal operation 21 Setting the basic brightness luminosity of the LEDs 21 Setting of the display modes 21 13 Technical data 23 Fieldbus 23 Power supply 23 Housing colors 23 Ambient conditions 23 Un...
Страница 6: ...ded for use in industrial environments They may only be operated within the limit values stipulated by the technical data When configuring installing maintaining and testing the units the safety and a...
Страница 7: ...so to be kept short due to any interference which might be emitted by the shielding Neither excessively long cables nor cable loops may be placed inside the units The connection of the cable shielding...
Страница 8: ...it construction The following figure shows model type S302 05 10 xx xxx xx xx as example for the other model types The front frame of the housing is locked with quick action releases When opening the...
Страница 9: ...SPS Siemens S7 1513 1 PN Operating system Microsoft Windows 7 Professional 64 Bit English The quick start describes the parameterization of the display Operation of the TIA Portal is required The devi...
Страница 10: ...nnection is shown Step 5 Add sub module to the display and define address range Add the module Numerical Value from the hardware catalog to the device overview This specifies that the display expects...
Страница 11: ...ta is transferred successfully to the display the configuration is displayed as follows in the engineering tool Step 7 Download configuration in the controller After the control can connect via PROFIN...
Страница 12: ...RT 1 00 12 27 Step 8 Transmit data to the display To transmit a value to the display you can for example create a function chart with the instruction MOVE In the following screenshot the number 1234 i...
Страница 13: ...t ASCII and Attribute are added automatically This specifies that the display occupies two blocks in the output data area 20 bytes for the text and 2 bytes for the attributes Step 6 and 7 See quick st...
Страница 14: ...g sent to the display can be up to 20 bytes long The displayed bytes are dependent on the scope of the display The not shown sequence bytes are ignored The attributes are binary coded Its structure is...
Страница 15: ...rk parameters multiple device names command of undefined properties or other fieldbus errors Once the connection has been established the following messages can be displayed With a 4 digit display Unt...
Страница 16: ...f the decimal points Offset scale factor multiplier and divisor for the conversion formula of the numerical value Upper and lower thresholds for automatically changing the display mode Luminosity of t...
Страница 17: ...Scale Factor 3 SINT16 1 Divisor 12 UINT16 unsigned 1 The calculation is based on the following linear function Displayed value offset scale factor multiplier divisor x sent value As a scale factor in...
Страница 18: ...s 10 UINT8 1 Minimum width 11 UINT8 30 The minimum number of digits displayed is defined as Minimum number of digits If the value to be displayed has less digits than Minimum number of digits the disp...
Страница 19: ...kening 0 100 100 100 16 003F Low beaming 0 25 50 100 16 001B High beaming 100 50 25 0 16 00E4 If the value 0 is entered in all four fields the display switches to a pulsating display This prevents an...
Страница 20: ...letely when the value exceeds the maximum display capacity Invalid initial value If the value sent to the display is invalid is shown on each position Overflow If the value sent to the display is that...
Страница 21: ...maximum luminosity 3 out of range luminosity 0 off 8 middle luminosity default 15 maximum luminosity 4 Blanking of the display 0 Display is dark all others display lights default Example To darken the...
Страница 22: ...n mode 1 Decimal Dots numeric INT32 2 Offset numeric INT32 3 Scale Factor numeric INT32 4 Range Upper bound numeric INT32 5 Range Lower bound numeric INT32 6 Flags numeric INT32 7 Standard attribute n...
Страница 23: ...pe terminals for the power supply are located on the power supply unit in the bottom section of the housing They have the following designations Devices for a power supply 115 V AC or 230 V AC L N and...
Страница 24: ...sheet 2 layer powder coated 1 Housing Stainless steel V2A powder coated 2 Housing Stainless steel V2A brushed 3 Housing Stainless steel V4A brushed 5 Protection type IP54 0 Protection type IP65 1 Pro...
Страница 25: ...5 digits 5 digits S302 x5 06 xx 1xx xx xx 15 S302 x5 06 xx 2xx xx xx 21 S302 x5 10 xx 1xx xx xx 23 S302 x5 10 xx 2xx xx xx 38 S302 x5 16 xx 1xx xx xx 77 S302 x5 16 xx 2xx xx xx 146 S302 x5 25 xx 1xx x...
Страница 26: ...1xx xx xx 480 245 110 16 7 8 S302 04 16 xx 1xx xx xx S302 F3 16 xx 1xx xx xx 670 300 110 20 9 11 S302 04 25 xx 1xx xx xx S302 F3 25 xx 1xx xx xx 1030 400 110 20 9 18 5 digits 4 digits dimension S302 0...
Страница 27: ...170 7 S302 04 10 xx 2xx xx xx S302 F3 10 xx 2xx xx xx 480 245 170 12 S302 04 16 xx 2xx xx xx S302 F3 16 xx 2xx xx xx 670 300 170 17 S302 04 25 xx 2xx xx xx S302 F3 25 xx 2xx xx xx 1030 400 170 27 5 d...