Functional Description of the Connectors/Interfaces
sinudyn-36
Hardware Description 0360520xx
47
8.2.11
X40 - Restart Lock according to Safety Category 3
Valid up to device state 0002:
X
6-pole MiniCombiCon
If no restart lock is used, the wiring should be carried out as follows:
Pin
Function
1
Input signaling contact K2/K3
2
Output signaling contact K2/K3
3
0 Volt trip coil of the relay K2
4
+24 V (30mA) trip coil of the relay K2
5
0 Volt trip coil of the relay K3
6
+24 V (30mA) trip coil of the relay K3
Warning
24 V and 0 V must always be connected for K2 and K3, also if the
restart lock is not to be used!
Warning
If the restart lock is to be used, please take the information from
chapter "Restart Lock“ on
into account!