Status Display and Error Messages
Code
Error message
Error reaction
Possible reason
9
Communication error between
DSP and safety controller
9
Safety function SFM/SLOF: com-
munication between DSP and safe-
ty controller is disturbed
E47
(0x52F)
(1327
d
)
Drive parameters not activated
Power output stage can not be acti-
vated.
▶
Drive start is not acknowledged by
master yet (configurable by parame-
ters in software).
E55
(0x737)
(1847
d
)
Firmware stopped by ESC
Device stops in BIOS.
▶
During boot-up, the device received
an ESC sequence at the serial inter-
face.
E56
(0x738)
(1848
d
)
Device configuration
Device stops in BIOS.
▶
During boot-up the device detected
that hardware, firmware parameters
and logic are not consistent;. A de-
tailed error description is received by
a parameter download.
E57
(0x739)
(1849
d
)
Faulty or no firmware
Device stops in BIOS.
▶
During boot-up the device detected
no firmware or a faulty firmware.
E58
(0x73A)
(1850
d
)
FPGA watchdog triggered
Device stops in BIOS.
▶
FPGA process monitoring has
been triggered;. Please contact
SIEB & MEYER.
E59
(0x73B)
(1851
d
)
No drive parameters loaded
Device stops in BIOS.
▶
Device is not parameterized (status
of delivery).
E60
(0x73C)
(1852
d
)
Drive parameters incorrect
Device stops in BIOS.
▶
Parameter set of the device is not
valid (CRC error).
E61
(0x73D)
(1853
d
)
Logic coding missing or incorrect
Device stops in BIOS.
▶
Logic programming of the device is
not valid.
E62
(0x73E)
(1854
d
)
Error in electronic type plate
Device stops in BIOS.
▶
Type plate is not programmed
or faulty. Please contact
SIEB & MEYER.
(1)
For servo motors with commutation via an incremental motor measuring system, the warning W17 “Unknown commuta-
tion angle” is signaled. After a restart of the device the phasing of the motor measuring system starts automatically (magnetic
alignment).
9.2.3
List of the Warning Messages
Warning messages are not displayed on the device display. They can only be seen in
the software
drivemaster2
via “Diagnosis → Errors and warnings”.
Code
Description
W00
Digital input 'Quick stop' active
W01
Digital input 'Positive limit switch' active
W02
Digital input 'Negative limit switch' active
W03
Voltage of mains supply not OK
W04
Power output stage load greater than parameterized warning threshold W04 (power output
stage I²t)
W05
Motor load greater than parameterized warning threshold W05 (motor I²t)
W06
Power output stage temperature greater than parameterized warning threshold W06
W07
Motor temperature greater than parameterized warning threshold W07
W08
DC link voltage greater than parameterized warning threshold W08
W09
DC link voltage less than parameterized warning threshold W09
W10
Speed controller in current limitation / PI limit
W11
Position/tracking error greater than parameterized warning threshold W11
W12
Speed error greater than parameterized warning threshold W12
W13
Tracking error of the current too great
W14
Ambient temperature greater than parameterized warning threshold W14
92
Drive System SD2M - Hardware Description 036228xxF