Code
Description
W00
Digital input 'Quick stop' active
W01
Digital input 'Positive limit switch' active
W02
Digital input 'Negative limit switch' active
W03
Voltage of mains supply not OK
W04
Power output stage load greater than parameterized warning threshold W04 (power output
stage I²t)
W05
Motor load greater than parameterized warning threshold W05 (motor I²t)
W06
Power output stage temperature greater than parameterized warning threshold W06
W07
Motor temperature greater than parameterized warning threshold W07
W08
DC link voltage greater than parameterized warning threshold W08
W09
DC link voltage less than parameterized warning threshold W09
W10
Speed controller in current limitation / PI limit
W11
Position/tracking error greater than parameterized warning threshold W11
W12
Speed error greater than parameterized warning threshold W12
W13
Tracking error of the current too great
W14
Ambient temperature greater than parameterized warning threshold W14
W15
Ballast resistor load greater than parameterized warning threshold W15 (ballast resistor I²t)
W16
Safety circuit is active
W17
Unknown commutation angle
W18
Hiperface / EnDat OEM data not valid
W19
Dirt signal encoder input 0
W20
Dirt signal encoder input 1
W21
Dirt signal encoder input 2
W22
Power supply unit load greater than 90% of the rated power
W23
Reserved
W24
Current or current rise greater than warning threshold W24 (warning current)
W25
Reference speed less than minimum motor speed
W26
Current greater than warning threshold W26 (warning overload current)
W27
Reserved
W28
Reserved
W29
Reserved
W30
Reserved
W31
Reserved
10.4
Message of the Quick Stop Functions
Code
Description
H01
Digital input "Switch on" waits for positive edge to switch the drive on (This function is only
active when the input is set as "Switch on type 2 (with positive edge)".)
H03
Software function "Quick stop"
H04
Digital input "Quick stop"
H07
Software positioning error "Negative limit"
H08
Software positioning error "Positive limit"
H09
Bus system "Quick stop" (The quick stop bit is set to 0)
H11
Digital input "Negative limit switch"
H12
Digital input "Positive limit switch"
Error Messages
W
64
Drive System SD2 - Safety Functions SFM / SLOF
10
Содержание SD2
Страница 1: ...Drive System SD2 Safety Functions SFM SLOF P TD 0000426 12 2019 08 28 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 Drive System SD2 Safety Functions SFM SLOF ...
Страница 10: ...General Information W 10 Drive System SD2 Safety Functions SFM SLOF 2 ...
Страница 16: ...Safe Frequency Monitor SFM W 16 Drive System SD2 Safety Functions SFM SLOF 3 ...
Страница 44: ...Fieldbus Communication W 44 Drive System SD2 Safety Functions SFM SLOF 6 ...
Страница 56: ...OSSD Signals W 56 Drive System SD2 Safety Functions SFM SLOF 8 ...