Code
Error message
Error reaction
Possible reason
5
Timeout of monitoring func‐
tions
5
Safety function SFM/SLOF: error
in according hardware
components
6
Monitoring of OSSD signals
and output stage enable
6
Safety function SFM/SLOF:
▶
wrong OSSD signals
▶
defective OSSD relay
▶
defective multiplexer
7
Monitoring of motor phases
7
Safety function SFM/SLOF: defec‐
tive motor cable (broken cable)
8
Frequency exceeded
8
Safety function SFM/SLOF:
▶
set reference speed value is
too high
▶
limit value for Safe Limited
Output Frequency is parame‐
terized incorrectly
▶
OSSD signals are set incor‐
rectly
9
Communication error
between DSP and safety
controller
9
Safety function SFM/SLOF:
communication between DSP and
safety controller is disturbed
E47
(0x52F)
Drive parameters not activated
Power output stage can not be
activated.
▶
Drive start is not acknowledged by
master yet (configurable by para‐
meters in software).
E55
(0x737)
Firmware stopped by ESC
Device stops in BIOS.
▶
During boot-up the device received
an ESC sequence at the serial
interface.
E56
(0x738)
Device configuration
Device stops in BIOS.
▶
During boot-up the device detected
that hardware, firmware parame‐
ters and logic are not consistent; a
detailed error description is
received by a parameter download.
E57
(0x739)
Faulty or no firmware
Device stops in BIOS.
▶
During boot-up the device detected
no firmware or a faulty firmware.
E58
(0x73A)
FPGA watchdog triggered
Device stops in BIOS.
▶
FPGA process monitoring has
been triggered; please contact
SIEB & MEYER.
E59
(0x73B)
No drive parameters loaded
Device stops in BIOS.
▶
Device is not parameterized (status
of delivery).
E60
(0x73C
Drive parameters incorrect
Device stops in BIOS.
▶
Parameter set of the device is not
valid (CRC error).
E61
(0x73D)
Logic coding missing or incorrect
Device stops in BIOS.
▶
Logic programming of the device is
not valid.
E62
(0x73E)
Error in electronic type plate
Device stops in BIOS.
▶
Type plate is not programmed or
faulty;
please
contact
SIEB & MEYER.
(1)
For servo motors with commutation via an incremental motor measuring system the warning W17
“Unknown commutation angle ” is signaled. After a restart of the device the phasing of the motor measuring
system starts automatically (magnetic alignment).
10.3
List of Warning Messages
Warning messages are not displayed on the device display. They can only be seen in
the software
drivemaster2 via “Diagnosis
ÿ
Errors and warnings”.
W
Error Messages
Drive System SD2 - Safety Functions SFM / SLOF
63
10
Содержание SD2
Страница 1: ...Drive System SD2 Safety Functions SFM SLOF P TD 0000426 12 2019 08 28 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 Drive System SD2 Safety Functions SFM SLOF ...
Страница 10: ...General Information W 10 Drive System SD2 Safety Functions SFM SLOF 2 ...
Страница 16: ...Safe Frequency Monitor SFM W 16 Drive System SD2 Safety Functions SFM SLOF 3 ...
Страница 44: ...Fieldbus Communication W 44 Drive System SD2 Safety Functions SFM SLOF 6 ...
Страница 56: ...OSSD Signals W 56 Drive System SD2 Safety Functions SFM SLOF 8 ...
Страница 66: ...Error Messages W 66 Drive System SD2 Safety Functions SFM SLOF 10 ...