6.3.1
Setting: Limit “Speed Zero” = 10 Hz
Set value for drive A in processor M0:
Index
Hexadecimal value
Decimal value
467
0x0000000A
10
468
0x74008100
1946190080
469
0x0000000A
10
470
0x73018100
1929478400
Set value for drive A in processor M1:
Index
Hexadecimal value
Decimal value
467
0x0000000A
10
468
0xF4008180
4093673856
469
0x0000000A
10
470
0xF3018180
4076962176
Set value for drive B in processor M0:
Index
Hexadecimal value
Decimal value
467
0x0000000A
10
468
0x73008101
1929412865
469
0x0000000A
10
470
0x72018101
1912701185
Set value for drive B in processor M1:
Index
Hexadecimal value
Decimal value
467
0x0000000A
10
468
0xF3008181
4076896641
469
0x0000000A
10
470
0xF2018181
4060184961
6.3.2
Query: Limit of “Speed Zero”
Query to drive A in processor M0:
Index
Hexadecimal value
Decimal value
467
0x00000000
0
468
0xFE000100
4261413120
469
0x0000000A
10
470
0xF3010100
4076929280
Query to drive A in processor M1:
Index
Hexadecimal value
Decimal value
467
0x00000000
0
468
0x7E000180
2113929600
469
0x0000000A
10
470
0x73010180
1929445760
W
Fieldbus Communication
Drive System SD2 - Safety Functions SFM / SLOF
33
6
Содержание SD2
Страница 1: ...Drive System SD2 Safety Functions SFM SLOF P TD 0000426 12 2019 08 28 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 Drive System SD2 Safety Functions SFM SLOF ...
Страница 10: ...General Information W 10 Drive System SD2 Safety Functions SFM SLOF 2 ...
Страница 16: ...Safe Frequency Monitor SFM W 16 Drive System SD2 Safety Functions SFM SLOF 3 ...
Страница 44: ...Fieldbus Communication W 44 Drive System SD2 Safety Functions SFM SLOF 6 ...