Default value
Response
Exemplary data
3
Time
(00HHMMSS) 0x000B1E01 = 11:31:01
“s01001v09003”
4
File name [3..0] 0x30313073 = “010s”
5
File name [7..4] 0x30763130 = “0v10”
6
File
name [11..8]
0x33303039 = “3009”
“SFM/SLOF”
7
Comment [3..0] 0x2F4D4653 = „/MFS“
8
Comment [7..4] 0x464F4C53 = „FOLS“
...
22
Comment [63..6
0]
6.2.4
Pattern
The PLC can generate any pattern byte. A new pattern can be sent with each trans‐
mission.
The received pattern is incremented by 1 in the controller and returned with the next
telegram. The PLC can check both patterns.
6.2.5
Check
Check contains the check sum that is calculated from the bytes 0 to 6.
To calculate the check sum the bytes 0 to 6 must be added byte-by-byte and
subtracted from the value 0xFF.
å
=
-
=
6
0
0
i
i
Byte
xFF
Check
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Sum
Check = 0xFF − Sum
0x81
0x03
0x01
0x02
0x03
0x04
0xAA
0x38
0xFF − 0x38 = 0xC7
6.3
Examples for Data Transmission
For data transmission adhere to the following order of object accesses:
▶
Write object: 4 bytes (reference value) in object 467
▶
Write object: 4 bytes (control data) in object 468
▶
Read object: 4 bytes (actual value) from object 469
▶
Read object: 4 bytes (status data) from object 470
Fieldbus Communication
W
32
Drive System SD2 - Safety Functions SFM / SLOF
6
Содержание SD2
Страница 1: ...Drive System SD2 Safety Functions SFM SLOF P TD 0000426 12 2019 08 28 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 Drive System SD2 Safety Functions SFM SLOF ...
Страница 10: ...General Information W 10 Drive System SD2 Safety Functions SFM SLOF 2 ...
Страница 16: ...Safe Frequency Monitor SFM W 16 Drive System SD2 Safety Functions SFM SLOF 3 ...
Страница 44: ...Fieldbus Communication W 44 Drive System SD2 Safety Functions SFM SLOF 6 ...
Страница 56: ...OSSD Signals W 56 Drive System SD2 Safety Functions SFM SLOF 8 ...
Страница 66: ...Error Messages W 66 Drive System SD2 Safety Functions SFM SLOF 10 ...