Requirements to the motor cable
The maximum admissible length of the motor cable is 100 m. The capacity must not
exceed 5.2 nF.
Example: If the cable capacity is 0.26 nF per meter, the maximum admissible length of
the motor cable is 20 m.
9.11
X64/X65 – EtherCAT
Ethernet connection cable: To connect EtherCAT devices use only Ethernet cables of
Category 5 (Class D) and higher. You can either use patch cables (1:1) or crossover
cables (TX crosslinked to RX) because the receiver ports (PHY) support automatic
cable recognition (auto crossover feature).