![SIEB & MEYER 0362171DA1 Series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/sieb-and-meyer/0362171da1-series/0362171da1-series_hardware-description_1264945058.webp)
Safety circuit / restart lock (STO)
Fig. 15: Safety circuit control
DANGER
No torque at restart lock activated
The motor cannot provide a torque when the restart lock is activated. Thus
non-self-locking drives could be released.
→ Non-self-locking drives as hanging loads must be blocked with a me-
chanical brake.
10.2
Wiring Example
Combining a safe emergency stop command device, an OSSD safety switch device or
a light barrier with OSSD outputs and the safe switching off of the pulse patterns al-
lows creation of an error detection circuit, which achieves a safe stop (according to stop
function category 0+1), which meets the safety requirements according to SIL 3 (EN
ISO 13849-1). This circuit allows connecting several emergency stop devices in parallel,
which are permanently monitored.
58
Drive Amplifier SD2B plus - 0362171DA1xxxx, 0362171DB1xxxx