8.2.2
Diagnostic faults for the WLL180T
Error code
Description
0x12
End of the data
0x13
Attempt to write blocked parameters
0x14
Teach different output channel
0x15
Attempt to apply 2-point teach to a mode that does not support it
0x16
Forbidden parameter value for warm start or initialization
0x17
Parameter value outside of permitted limits
0x18
Index value outside of permitted limits
0x19
Attempt to teach counter mode
0x1B
Received light value too weak during teach-in
0x1C
Received light value too high during teach-in
0x1D
Difference in received light values between first and second point too
small during 2-point teaching
8.2.3
Communication error
Error code
Description
0xB0
Forbidden index value
0xB1
Forbidden data length
0xB2
Forbidden slot number
0xB6
Access denied
0xB8
Defective parameters