Annex
Range
Meaning
Byte 26
–
27
ChannelNumber
Byte 28
–
29
ChannelProperties
Byte 30
–
31
ChannelErrorType
The following values exist for ChannelErrorType:
ChannelErrorType
Meaning
0x40
Incorrect failsafe destination address (F_Dest_Addr)
0x41
Invalid failsafe destination address (F_Dest_Add)
0x42
Invalid failsafe source address (F_Source_Add)
0x43
Failsafe monitoring time is 0 ms (F_WD_Time)
0x44
Parameter F_SIL exceeds the maximum SIL for the device
0x45
The parameter F_CRC_Length does not correspond to the value
generated
0x46
Incorrect version of the F parameter
0x47
CRC1 fault
0x100
Device in error state
0x101
Device in configuration state
0x102
New configuration data
0x103
Configuration required
0x104
PROFINET configuration error
0x105
PROFIsafe parameterization error
0x106
PROFIsafe communication inactive
0x107
EFI1 communication error
0x108
EFI2 communication error
0x109
Undervoltage detected
0x200
Error in safety-related communication on EFI1
0x201
Physical data transmission error on EFI1
0x202
Invalid configuration on EFI1
0x203
Device restart on EFI1 detected
0x204
General error in EFI1 communication
0x205
Safety-related communication on EFI1 inactive
0x300
Error in safety-related communication on EFI2
0x301
Physical data transmission error on EFI2
0x302
Invalid configuration on EFI2
0x303
Device restart on EFI2 detected
0x304
General error in EFI2 communication
0x305
Safety-related communication on EFI2 inactive
Tab. 20: Additional
diagnostics of the UE4740
Tab. 21: Values for
ChannelErrorType on the
UE4740