Operating Instructions
Chapter
12
UE4155
8010178/TF82/2010-03-05
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
73
Subject to change without notice
Annex
12.3.4
Diagnostics data of devices on the SDL connections
The diagnostics data of the SDL connections are twelve bytes in length for each connec-
tion. Their structure depends on the device which is connected to the corresponding SDL
connection. To this end, please read the operating instructions of the UE4155 function
package for the device in question.
Diagnostics data of the 1st device on SDL connection 1 (Host)
Address
26.7
26.6
26.5
26.4
26.3
26.2
26.1
26.0
C4000 Standard/Advanced
M4000 Advanced
S3000
S300
Reserved
Contami-
nation
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Address
27.7
27.6
27.5
27.4
27.3
27.2
27.1
27.0
C4000 Standard/Advanced
Emergency
Stop status
Selected operating mode of the C4000
(000 = none, 001–110 = 1–6)
M4000 Advanced
Reserved
Reserved
Reserved
Reserved
Status of the monitored-case inputs on the S3000
S3000
In B2
In B1
In A2
In A1
S300
Reserved
Reserved
Reserved
Reserved
Operational status of the
device
00: Operation
01: Initialisation
10: Configuration mode
11: Lock
D
out
Device error
Reserved
Address
28.7
28.6
28.5
28.4
28.3
28.2
28.1
28.0
C4000 Standard/Advanced
Diagnostics
protective field
00: Error
01: Invalid PSDI
interruption
10: Valid PSDI
interruption
11: No object/no PSDI
interruption
Teach-in
active
Teach-in
key-
operated
switch
operated
M4000 Advanced
Reserved
Reserved
Reserved
Reserved
Status of the monitored-case inputs on the S3000
S3000
In D2
In D1
In C2
In C1
S300
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Address
29.7
29.6
29.5
29.4
29.3
29.2
29.1
29.0
C4000 Standard/Advanced
Status
bypass
M4000 Advanced
S3000
S300
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved