Approach
1.
Switch off the supply voltage.
2.
Ensure that connected hardware is not damaged by the 24 V output voltage.
3.
Press and hold the
T2
pushbutton.
4.
Press and hold the
T2
pushbutton to switch on the supply voltage.
5.
Press and hold
T2
for 6 seconds until
LED 4
lights up and
LED 3
flashes.
✓
LED 4
lights up green.
✓
LED 4
flashes orange 1x: device automatically selects current or voltage output
(factory setting).
✓
LED 4
flashes orange 2x: voltage output.
✓
LED 4
flashes orange 3x: current output.
✓
LED 4
flashes orange 4x: push-pull digital output.
6.
To change the setting, press
T2
for 1 second.
7.
Wait 10 seconds.
✓
The pin 2 output is set. The device automatically switches to normal operation
mode.
7.3.2
Digital output 1 teach-in
7.3.2.1
Factory settings of the digital output
•
N/O contact
•
Switching point at maximum operating range
7.3.2.2
Teaching in switching point (Single Point Mode)
Overview
When the object is located below the taught-in switching point, the digital output is
active.
Approach
Teaching in the switching point (distance to object as switching point)
1
1.
Position the object at
1
.
2.
Press
T2
pushbutton for 3 seconds until
LED 1
and
LED 2
flash simultaneously.
✓
LED 1
and
LED 2
flash alternately.
3.
Press
T2
for 1 second.
✓
The switching point is taught in. The device automatically switches to normal
operation mode.
Teaching in switching point (distance to 8% as switching point)
1.
Position the object at
1
.
2.
Press
T2
pushbutton for 3 seconds until
LED 1
and
LED 2
flash simultaneously.
✓
LED 1
and
LED 2
flash alternately.
3.
Press
T2
for 3 seconds until
LED 1
and
LED 2
flash alternately again.
✓
The switching point is taught in. The device automatically switches to normal
operation mode.
7
OPERATION
22
O P E R A T I N G I N S T R U C T I O N S | UC40
8027772//2022-08-11 | SICK
Subject to change without notice