![SICK TR110 Lock Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/sick/tr110-lock/tr110-lock_operating-instructions-manual_1264391025.webp)
5.3
Mounting the safety switch
Important information
NOTICE
The actuator must not be used for guiding or used as a stop.
Prerequisites
•
To mount on the machine, the safety switch and actuator must be put together.
•
A clearance of 12 mm must be maintained around the actuating head.
Approach
The safety locking device may be in any installation position.
b
Mount the safety switch using 4 × M5 screws.
b
Observe the maximum tightening torque of 1.4 Nm.
Figure 18: Mounting the safety switch
1
Mounting holes
2
12 mm clearance for actuator
Complementary information
Mounting brackets are available for the actuator and safety locking device as acces‐
sories (
see "Dimensional drawings of the mounting bracket", page 60
).
5.4
Mounting straight and angled actuators
Important information
NOTICE
The actuator must not be used for guiding or used as a stop.
MOUNTING
5
8023119/15LY/2019-10-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | TR110 Lock
25
Subject to change without notice