5
Mounting
5.1
Safety
DANGER
Hazard due to unexpected starting of the machine
Death or severe injury
b
Make sure that the dangerous state of the machine is and remains switched off.
DANGER
Bypassing the protective device
Hazard due to lack of effectiveness of the protective device
1.
Avoid incentives to manipulate the safety switch by means of the following mea‐
sure:
°
Use permanent mounting methods for actuators (e.g. welding, adhesive
bonding, safety screws or rivets).
2.
Observe the design requirements in accordance with ISO 14119 for mounting:
°
Reduction of bypass possibilities of an interlocking device
°
Mounting of safety switch and actuator
NOTICE
Incorrect mounting and unsuitable ambient conditions may damage the safety switch.
b
Arrange the sensor and actuator in a way that prevents damage from foreseeable
external influences.
b
Do not use the sensor and actuator as a stop.
b
The holder and mounting method for the sensor and actuator must be stable
enough to ensure that correct operation can take place.
b
Always use reliable mounting elements that can only be removed using tools.
b
If misalignment results in an opening on the physical guard, this must not impair
the protection that is provided.
5.2
Unpacking
b
Check the components to ensure that all parts are complete and undamaged.
b
Please contact your respective SICK subsidiary should you have any complaints.
5.3
Mounting
Selecting the mounting location
CAUTION
Bypassing the safety switch in a simple way or unintentional actuation must be pre‐
vented by suitable installation measures in accordance with ISO 14119.
If the mounting location is not specified by the machine documentation, it must be cho‐
sen carefully.
5
MOUNTING
20
O P E R A T I N G I N S T R U C T I O N S | T4000 Multi
8022726/2019-05-07 | SICK