11.3
Mechanics and electronics
Feature
Parameter
Electrical connection
POWER: 1 x M12, 4-pin male connector, A-
coded
CONFIG: M8, 4-pin female connector
SENSOR S1 - S4, IO-Link master: 4 x M12,
5-pin female connector, A-coded
ETHERNET: 2 x M12, 4-pin female connector,
D-coded
Supply voltage
10 ... 30 V DC
Operating current
Must be limited by external power supply unit
to max. 4 A
Power consumption
4.2 W max., without connected sensors
Power output
Max. 72 W total (all connections)
Output current
SENSOR S1 - S4, IO Max. output current to switching output pins:
200 mA
SENSOR S1 - S4, IO Max. output current to power supply pins:
500 mA
Housing material
zinc
Housing color
Black
Protection class
III
Short-circuit protection
In accordance with VDE 0160
Weight
520 g
Dimensions (W x D x H)
213.9 x 57 x 38.3 mm
11.4
Ambient data
CAUTION
This equipment is not intended for use in residential areas and may not provide ade‐
quate protection against radio reception in these environments.
Feature
Parameter
Electromagnetic compatibility (EMC)
EN 61000-6-2
EN 61000-6-4
Vibration resistance
EN 60068-2-6
Shock resistance
EN 60068-2-27
Enclosure rating
IP67 (requires blind plugs to be inserted into
unused connections)
1
Ambient operating temperature
-40 °C ... +55 °C
Storage temperature
-40 °C ... +75 °C
Permissible relative humidity
90%, non-condensing
1
When cables are not attached, the connection caps delivered with the device must be tightened with
0.35 Nm.
TECHNICAL DATA
11
8026126//2020-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | SIM200
25
Subject to change without notice