Resolution
The resolution of an active opto-electronic protective device (also
known as the sensor detection capability) is the minimum size of
an object for it to be reliably detected.
Response time
The protective device’s response time is the maximum time
between the occurrence of the event leading to the sensor’s
response and supply of the switch-off signal to the protective
device’s interface (for example OFF state of the OSSD pair).
Restart interlock
The restart interlock prevents the machine from automatically
starting up, for example after a protective device has responded
while the machine is operating or after changing the machine’s
operating mode.
The restart interlock can be implemented in the protective device
or in the safety controller.
A command to reset the protective device must be given, for exam‐
ple using a reset pushbutton, before the machine can be
restarted.
SIL
Safety integrity level
SILCL
SIL claim limit (IEC 62061)
Start interlock
The start interlock prevents the machine from automatically start‐
ing up, for example after if the voltage supply of the electro-sensi‐
tive protective device (BWS) is switched on or is restored after an
interruption.
Warning field
The warning field monitors larger areas than the protective field.
Simple switching functions can be triggered with the warning field,
e.g. a warning light or an acoustic signal can be triggered if a per‐
son approaches, even before the person enters the protective
field.
The warning field must not be used for safety applications.