Operating instructions Register sensors RS25
Commissioning
32
© SICK AG • Presence Detection • Subject to change without notice • 8015887
8.3
Operation via the evaluation unit
8.3.1
Selecting parameters
You can select a menu, parameter, or option using the
SET
, and push-
buttons.
→
For the overall menu structure see Page 31, Fig. 17.
8.3.2
Selecting options
1. Select the desired parameter using the
SET
, and pushbuttons.
2. Select the desired option using the or pushbuttons.
3. Complete one of the following steps:
• Press the
SET
pushbutton to save the change.
• Press the
ESC
pushbutton to cancel the process. The parameter name
is displayed again.
4. Complete one of the following steps to return to the status indicator:
• Press the
ESC
pushbutton repeatedly until the status indicator is
displayed again.
• Wait for approx. one minute. The display will automatically switch
back to the status indicator if no buttons are pressed. Any settings
you have made will also be saved.
8.3.3
Changing the value
1. Select the desired parameter using the
SET
, and pushbuttons.
2. Press the
SET
pushbutton. The current value of the parameter is dis-
played. The first digit on the left flashes.
3. Press the pushbutton to increase the digit. Press the
push button
to lower the digit.
4. Press the
SET
pushbutton to save the digit entered. The next digit
flashes.
Press the
ESC
pushbutton to cancel the process.
5. Repeat steps 3 and 4 until the last digit is saved. The parameter name
is displayed.
6. Press the
ESC
pushbutton repeatedly until the status indicator is
displayed again. Alternatively, you can wait for approx. one minute.
The display will automatically switch back to the status indicator if no
buttons are pressed.