Appendi
x
10
Appendix
11.1 Appendix overview
The appendix contains the following additional information:
¾
Configuring the RFH620 System with command strings
¾
Ordering information
¾
Glossary
¾
Copy of EC Declaration of Conformity
11.2 Configuration the RFH620 with command strings
As an alternative to the SOPAS-ET configuration software, the RFH620 can also be
configured and operated with command strings via all the data interfaces. The command
strings can be displayed separately via the SOPAS-ET configuration software.
Both the command strings and the SOPAS-ET configuration software are based on
command language which directly accesses the command interpreter of the bar code
scanner. This command language must be used with care as the RFH620 executes sent
commands immediately. Parameter values altered via commands are at first only active
in the current parameter set in the working memory (RAM) of the bar code scanner. To
save in the permanent memory, the altered parameter set must be copied into the PROM
using a special command, this ensures that the alterations are not lost when the power
supply is switched off.
Command strings for triggering the reading pulse:
-
START: <STX>sMN mTCgateon<ETX>
-
STOP: <STX>sMN mTCgateoff<ETX>
If the commands are entered via the terminal emulator in the SOPAS-ET configuration
software, the two control characters <STX> and <ETX> are omitted. Connection to the
RFH620 when using the terminal emulator and Ethernet:
1. Select TOOLS/TERMINAL in the SOPAS-ET configuration software menu to call
up the terminal emulator and in the terminal emulator, select CONNECTION/
CONNECT to call up the connection assistant.
2. Select option USER DEFINED CONNECTION in the connection assistant and
confirm by pressing NEXT.
3. Select option TCP/IP and confirm by pressing NEXT.
4. Select option SHOW ONLY COLA TELEGRAMS.
5. Enter the RFH620's IP address in the relevant field and confirm by pressing NEXT.
6. In the ADDRESSING MODE selection list, select BY NAME and confirm the
settings by pressing CONNECT. The connection with the RFH620 is established.
The command strings can be transferred.