Chapter
10
Operating instructions
RFID Access Management
102
Operating instructions | SICK
8018582/2015-11-03
Subject to change without notice
Technical data
10.1.4
CDB650 connection module data sheet
Supported products
RFU62x, RFU63x
Optical indicators
11 x LED
Electrical connections
1 x 17-pin M12 female connector, A-coded
1 x 9-pin D-Sub male connector, internal
Spring-loaded terminals: 8 for wires 0.14 mm
2
2.5 mm
2
/ 29 for wires 0.14 mm
2
up to 1 mm
2
Cable glands
5 x M16, clamping range Ø 4.5 mm to 10 (7) mm
Supply voltage
10 V DC... 30 V DC
Power consumption
1 W
Enclosure rating
IP 65 (DIN 40 050)
Protection class
III (VDE 0106)
Rel. air humidity
90%
non-condensing
Operating temperature
-40 °C to +50 °C
Weight
265 g (without optional CMC600)
Tab. 22: CDB650 connection module data sheet
10.1.5
CMC600-101 cloning module data sheet
Description
External parameter memory for integration in
CDB620/CDB650/CDM42x
Additional switching inputs
2, opto-decoupled, Ue = max. 32 V
Additional switching outputs
2, PNP, I
a
= max. 100 mA, short-circuit protected
Optical indicators
2 x LED
Supply voltage
10 V DC
…
30 V DC (via CDB650)
Power consumption
500 mW
Electrical safety
Acc. to EN 60950-1 (2006)
Weight
30 g
Operating temperature
-35 °C to +40 °C
Tab. 23: CMC600-101 cloning module data sheet