Properties
Data
min. type max.
Warning field output (PNP)
Voltage: Warning field clear
U
v
- 2.5 V
Voltage: Warning field clear
13.4 V
at U
v
= 16.8 V
Switching current
(referred to EXT_GND)
100 mA
Time behaviour of output
without restart inhibit
Deactivation depends on scan
rate, activation does not.
Deactivation after WF incursion
(double-speed
scanning)
127
ms
Activation on warning field (WF) clear
40 ms
Time behaviour of output
after 2 seconds
Depends on scan rate
Deactivation after WF incursion
(double-speed
scanning)
127
ms
Activation on warning field (WF) clear
40 ms
Short-circuit protected
Yes
Switching frequency
3 Hz
Load
inductivity
2
H
Safety outputs (OSSD)
– dynamic (HIGH active)
Switching voltage
HIGH active (U
eff
)
U
v
- 2.5 V