5 Installation/Mechanical connection
Figure 8: Switch panel mounting set
max. R2
40
+
3
0
54
+
3 0
Figure 9: Opening in the switch panel
•
Insert the switch panel mounting frame into the switch panel from the
outside.
•
Secure the fixing element in the mounting rail support for the pressure
switch.
•
Insert the pressure switch into the switch panel mounting frame support
from behind until you can see and feel it lock into place.
•
Carefully tighten the two fixing screws as far as possible and secure the
fixing screws (4 Ncm) using the counter nuts.