b
If necessary, change the position of the test object so that a thorough check is car‐
ried out for each monitoring case to determine whether the protective field is
active over the whole of the required width.
b
Check the height of the scan plane. The scan plane must be at a height of at least
200 mm so that people lying down can be reliably detected. For this purpose, posi‐
tion the supplied test object at a number of points at the edges of the area largest
protective field. The safety laser scanner must detect the test object at each posi‐
tion and indicate the detection. How it is indicated depends on the configuration.
If the thorough check reveals a fault, the machine should be shut down immediately. In
this case, the mounting and electrical installation of the safety laser scanner must be
checked by appropriately qualified safety personnel.
Thorough visual check of the machine and the protective device
SICK recommends the following procedure:
b
Check whether the machine or the protective device has been modified or manipu‐
lated so that the effectiveness of the protective device may be impaired.
b
Check the following points in particular.
°
Has the machine been retrofitted?
°
Have machine parts been removed?
°
Have modifications been made to the machine’s surroundings?
°
Are there any defective cables or open cable ends?
°
Have the protective device or its parts been dismantled?
°
Is the protective device damaged?
°
Is the protective device severely contaminated?
°
Is the optics cover contaminated, scratched or destructed?
°
Has the protective device’s alignment been changed?
°
Are there any objects (e.g. cables, reflective surfaces) in the protective field?
If one of the points applies, the machine should be shut down immediately. In this case,
the machine and the protective device must be checked by appropriately qualified
safety personnel.
PROJECT PLANNING
4
8023152/160F/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
57
Subject to change without notice