Chapter
6
Operating Instructions
CLX490 Compact OMNI Scanner
6-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Operation
6.4.2
Function of the tabs in CLV-Setup (overview)
Reading Configuration
This tab and further dialog boxes are used to set the following:
•
Scanning frequency
•
Start/stop ratio
•
Reading area (reading angle limits or three-dimensional reading space when the
conveyor is running)
•
Autofocus mode (object distance measurement, preference focus distance, delay of fo-
cus chance, depth of field optimization, autofocus space)
•
Reading distance configuration for event-controlled focus control (focus position,
assignment table)
•
Trigger source for the focus control (if event-controlled)
•
Adjustment to bar code characteristics
Device Configuration
This tab and further dialog boxes are used to set the following:
•
Device number
•
Source of the reading trigger mode
•
Laser timeout
•
Output time of the reading result referred to the start of the reading interval
•
Scanner position parameters (position of the CLX in the space)
•
Tracking parameters
•
Object polling parameters
•
Output filter of the reading result (host interface)
•
Physical arrangement for data output via the host interface
(stand-alone, master/slave)
•
Functional assignment of the "IN 4" switching input
•
Functional assignments of the "Result 1 to Result 4" switching outputs
•
Start option for accessing the parameter set
•
Match code
Code Configuration
This tab and other further dialog boxes are used to set the following:
•
Type of active decoder (SMART, SMART/Standard or Standard decoder)
•
Evaluation routines for individual code types
•
Number of identical reads (multiple reads)
•
Minimum and maximum number of bar codes to be read/output
•
Kind of Start/Stop recognition
•
Activation of the comparison of the reading angle for the separation of identical bar
codes
•
Special parameters of the SMART decoder (e. g. for OTS mode)
Recommendation
To enhance the reading reliability with fast applications, only activate those code types and
code lengths that are actually relevant.