Electrical installation
Connecting the CLX with external parameter memory
a) CLX without heater:
Connection Modules: AMV/S60, AMV30-071, BMV10
¾
Cover the connections on the CLX with the connector cover (parameter memory),
no. 2020307. Connect the plug/socket on the cables ("Host/Term" and " I/O"
connections) with the appropriate connections on the AMV/S or BMV10.
Connection Module: BMS20
¾
Cover the connections on the CLX with the connector cover (parameter memory)
no. 2020308. Connect the 9-pin plug ("Host/Term" connection) to the socket on the
BMS20. Connect the wires of the free cable end ( "I/O" terminal) to the terminal strips
in the BMS20.
Recommendation
Use the external parameter memory no. 2020981 (open cable ends) for connecting the de-
vice to non-SICK Power packs/wiring configurations.
b) CLX with heater:
Connection Module: AMV100/200
¾
AMV100: Cover the connections on the CLX with the connector cover (parameter
memory), no. 2021689, labeled ”SCANNER”. Connect the other connector covers, la-
beled "HOST", to the corresponding connections on the AMV100.
¾
AMV200: see AMV100,
proceed in the same way with the second CLX.
5.2.6
Connections/cables for the IP 65 connector cover
(connection to AMV100/200 or BMV10)
The connector cover (optional accessory) with 15-pin D Sub HD plug connections is used
to cover the terminals on the CLX so that the enclosure rating IP 65 is provided.
The connector cover is prefabricated with two cables, each of 3 m in length, and is available
with two different cable ends:
•
with one additional connector cover at the other end (pins assignment identical to that
of the CLX terminals), no. 2021298
•
with two open cable ends, no. 2021267
CLX with heater:
Both connector cover variants can be used with temperatures up to max. –50
°
C if the CLX
is stationary and the cables are not moved. If the cables are moved due to changes in the
position of the CLX, the temperature must not drop below max. –40
°
C.
Recommendation
Use the external parameter memory no. 2020267 (open cable ends) for connecting the de-
vice to non-SICK Power packs/wiring configurations.