Operating Instructions
CLX490 Compact OMNI Scanner
I-4
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Quick Finder
Installation procedure (overview)
Reading pulses via switching input "Sensor" (default setting)
1.
Check the delivery to make sure that none of the components is missing.
2.
Mount the CLX at the reading station and align it with the object carrying the bar code.
3.
Mount the AMV/S60 Connection Module.
4.
Connect the CLX to the AMV/S60 Connection Module using the two cables
no. 2020302. Alternatively, connect the device to the AMV/S60 via the external
parameter memory no. 2020307.
5.
Connect the reading pulse sensor to the "Sensor" switching input in the AMV/S60.
6.
Connect the host to the host interface in the AMV/S60.
Adapt the AMV/S60 to the host interface type of the CLX.
7.
Switch on the power supply to the AMV/S60.
The "Device Ready" LED lights up after the CLX has started.
CLX with external parameter memory (in connector cover) connected:
After the CLX has started, it copies the internal parameter set to the external parameter
memory if the memory is empty. Then the "Read Result" LED lights up.
8.
Switch on your PC and start Windows
TM
(minimum requirement: Windows 95
TM
).
9.
Install the "CLV-Setup" software and online CLV-Setup Help from the CD-ROM ("Manu-
als & Software") on your PC.
10. Connect the PC to the auxiliary interface of the CLX. To do so, connect the 3-core
RS 232 data cable (null modem cable) (e. g. no. 2014054) to the "Service plug" in the
AMV/S60.
11. Start the "CLV-Setup" program.
CLV-Setup establishes communication with the CLX and uploads the parameter set.
The parameters are then displayed on the tabs.
12. Carry out a test read using test bar codes (trigger the CLX accordingly).
Display the reading result in the Terminal Emulator window of the "CLV-Setup" program.
13. Configure the CLX for the application using the settings on the tabs in CLV-Setup. Copy
(download) the modified parameter set to the CLX temporarily.
Do
not
switch off the power to the AMV/S60 (CLX)!
14. Test the application under realistic conditions.
15. Check whether the data is transmitted correctly between the CLX and host.
16. If necessary, correct and optimize the parameter values.
Copy (download) the parameter set
permanently
to the CLX.
CLX with external parameter memory (in connector cover) connected:
Copy the modified parameter set to the external parameter memory when CLV-Setup
asks you for confirmation.
17. Save the parameter set as a configuration file "*.scl" in the "CLV-Setup" program.
The CLX can then be operated with the
application-specific
settings.