Operating Instructions
Chapter
10
CLX490
8009237/RB47/2007-08-03
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-13
Appendix
10.4.4
Electrical installation
Cable cross-section
The connection cables for the power supply must have a cross-section of at least
0.75 mm
2
.
See also
Chapter 5.4.2 Supply voltage, Page 5-8
Power consumption
The power consumption of the CLX with heater is typically 75 W and max. 90 W. These
values apply to operation without the switching outputs connected.
AMV/S60 Connection Module
The AMV/S60 Connection Module is not suitable to power the CLX with heater. An external
power supply pack with a higher power output should be used for this purpose.
See
Chapter 3.1.3 System requirements, Page 3-1
10.4.5
Outdoor applications
If the CLX with integrated heater is used outdoors, it should be installed in a protective hous-
ing to prevent the front window from being damaged by rain, snow, or dust. The housing also
acts as a wind protector.