7.3.12.1
Formatting settings
In the
Decimal separator
field, select whether the measured values in the *.csv file
should use a period or a comma as the decimal separator.
In the
Column delimiter
field, select whether the data columns in the *.csv file should be
separated by a comma or semicolon.
NOTE
*.csv files become illegible if a comma is used as both a decimal separator and column
delimiter.
7.3.12.2
Starting and testing the recording
Start recording
Click on the
Start recording
button to start recording measurement data. A new file for
storing the recorded measurement values is opened automatically.
Stop Recording
Click on the
Stop recording
button to stop recording measurement data. The opened file
is closed and saved on the device. If the maximum number of measurement values in
the preset parameters is reached before this, the file is closed automatically and saved
on the device.
7.3.12.3
Determining the allocation
In the Allocation field, the user can define the number of data entries to be saved until
the memory function is stopped. Values are possible from 1 to 100,000; the standard
value is 1,000.
7.3.12.4
Setting the interval
The intervals at which data is to be saved is set in this field. This means that data is
only saved periodically, thereby reducing the total quantity of stored data and simplify‐
ing any further processing.
NOTE
If the
Recording of single values
switching function was previously selected (
the switching function", page 53
), the
Interval
parameter is automatically changed to
“1”.
When the value is set to 1, all data is saved.
For values (n) greater than 1, only every nth measured value is saved.
Values are possible from 0 to 100,000; the standard value is 100.
7.3.12.5
Setting the start conditions
The following settings are possible:
Table 22: Settings for the recording start condition
Function
Meaning
Immediately (default value) Memory function starts immediately
Error off
Memory function starts as soon as measurements are possible
Error on
Memory function starts as soon as measurements are not possi‐
ble