11
Technical data
11.1
Performance
Parameter
Specification
Measuring range
25 mm,
±
1 mm
50 mm,
±
1 mm
100 mm,
±
1 mm
200 mm,
±
1 mm
Field strength
3 mT ... 12 mT
Resolution
≥
50
μ
m
Repeatability (at 25 °C)
1)
0.1 mm
Linearity error (at 25 °C)
2)
0.3 mm
Sampling rate
1 ms
3)
Partial stroke speed, typ.
≤
1.5 m/s
Full stroke speed, typ.
≤
3 m/s
Time delay before availabil‐
ity
1.5 s
1)
Repeatability with magnet movement from one direction
2)
Linearity error (maximum deviation) dependent on response curve and minimum deviation function
3)
Only in standard operation, not in IO-Link operation
11.2
Interfaces
Parameter
Specification
Outputs (analog)
1x current output, 1x voltage output
Output (digital)
1x digital switching output (pin 2)
IO-Link (v1.1), smart sen‐
sor profile
4 channels
Data storage, block parameter
BDC modes: single point mode, window mode, cylinder switch
mode, two point mode
Cycle time: min. 1 ms
11.3
Mechanics/electronics
Parameter
Specification
Electrical connection
1)
PUR cable 0.3 m; M8, 4-pin
or
PUR cable 0.3 m; M12, 4-pin
or
PUR cable 2 m; cable outlet (open strand end)
Supply voltage (U
v
)
12 ... 30 V DC, reverse polarity protected
3)
Residual ripple (V
ss
)
≤
10%
Power consumption (with‐
out load)
P
0
= 42 mA
2)
x U
v
Voltage output (analog)
0 V ... 10 V
Current output (analog)
4 mA ... 20 mA
Digital switching output
I
max
:
±
100 mA, U
out
: 0 V ≤ U
out
≤ U
V
- 2 V
Load resistance (current
output)
≤
500
Ω
4)
Load resistance (voltage
output)
≥
2 k
Ω
TECHNICAL DATA
11
8019721.1FIH/2022-06-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-C
35
Subject to change without notice