Suitable cable lugs
•
Forked cable lug or ring cable lug
•
Width ≤ 10 mm
•
Hole diameter for screw: typically 5.2 mm
6.3.3
Ethernet for EFI-pro, data output, configuration, and diagnostics (XF1, XF2)
On the device side, Ethernet and EFI-pro are connected via 4-pin, D-coding M12 female
connectors. There is a network switch in the safety laser scanner which connects the
two Ethernet female connectors. The two Ethernet female connectors therefore have
the same function. The pin assignment corresponds to EN 61918, Appendix H.
3
2
4
1
Figure 58: Network pin assignment (M12 female connector, 4-pin, D-coding)
Table 8: Network pin assignment
Pin
Designation Function
1
TX+
Send data +
2
RX+
Receive data +
3
TX–
Send data -
4
RX–
Receive data -
Thread
SH
Shielding
6.3.4
Local inputs and outputs 1 (XG1)
The local inputs and outputs are connected on the device side via 17-pin, A-coded M12
female connectors.
If both 17-pin connections are used, both 17-pin cables must be clearly marked to
prevent confusion when replacing the device.
1
2
6
7
14
12
3
4
5
8
9
10
11
13
15
17
16
Figure 59: Pin assignment of local inputs and outputs 1 (female connector, M12, 17-pin,
A-coded)
Table 9: Pin assignment for local inputs and outputs 1
PIN
Designation Function
1
2
3
4
5
Uni-I 01
Universal input 1, configurable:
•
•
Universal input: sleep mode, restarting the device, pausing
event recording
ELECTRICAL INSTALLATION
6
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
93
Subject to change without notice