LED status
Relevance
Troubleshooting
Ö
Red/green
Device self-test
Device is being config‐
ured
Configuration errors
b
Configure device.
9.3.3
Status indicator with the display
The display shows current information about the status of the safety laser scanner. The
display switches off after approx. 60 s if all fields are clear and no other notification is
displayed.
b
If the display is switched off, press any pushbutton to activate the display.
b
Press any pushbutton to obtain more details about the displayed status informa‐
tion.
b
If there are a number of pages with detailed information, this is shown in the top
right of the display.
b
Press the arrow buttons to change between a number of pages with detailed
information.
Table 24: Overview of status information
Display
Device or configura‐
tion
Meaning
All devices and config‐
urations
All fields clear, safety outputs in ON state.
The number at bottom right indicates the
active monitoring case.
A configured OSSD
pair
2 to 4 configured
OSSD pairs
For each of the 4 cut-off paths, the following
applies: The protective field is interrupted or
there is a warning field in the active monitoring
case. OSSD pairs in the OFF state.
Each column represents one OSSD pair.
OSSD pairs that are in the OFF state are
marked with a cross if they can be in the ON
state in at least one monitoring case.
2 to 4 configured
OSSD pairs
The protective field assigned to OSSD pair 3
is interrupted or there is a warning field in the
active monitoring case. OSSD pair 3 is in the
OFF state.
OSSDs for which no field is interrupted and
which are in the ON state are marked with their
number.
2 to 4 configured
OSSD pairs
Cut-off paths in which no protective field is
located are not marked. The associated OSSD
pair is in the OFF state.
OPERATION
9
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
155
Subject to change without notice