30
8024638/AE00/V1-0/2019-09| SICK
S E R V I C E M A N U A L | MCS200HW
Subject to change without notice
3
MAINTENANCE
.
Fig. 30: Ejector block, open
3
Replace the O-ring of the middle section.
4
Disconnect the nozzle with a 5 mm Allen key.
5
Replace the spring washer.
6
Fasten the nozzle and spring washer on the ejector block.
7
Fasten the middle section with new screws.
3.4.5.2
Replacing the sealing ring on hose connection 2
1
Disconnect hose connection 2 with a jaw wrench.
Fig. 31: Ejector, hose connection 2
2
Remove the old sealing ring from the hose connection 2.
▸
Carefully remove sealing ring residues.
1 O-ring
2 Nozzle
Tools required
Phillips screwdriver
Slot screwdriver
Jaw wrench, size 14/19
5 mm Allen key
3 mm Allen key
2 mm Allen key
Scalpel
1 Sealing ring
2 Hose connection 2
NOTE: Leak tightness of the system
Damaged surfaces impair the leak tightness of the system.
Do not damage surfaces.