5.7.15.7.5
Dialogue external PC
Specialist
: Utilities: Service: Dialogue external PC
Dialogue with external PC: Only for service purposes
ASCII - Hex - switch-over: ALT H
Echo ON/OFF: ALT E
Menu exit: F2 or ALT X
5.7.15.7.6
Initialisation of I/O modules
Specialist
: Utilities: Service: Initialisation of I/O modules
5.7.15.7.7
STOP, START measure
Specialist
: Utilities: Service: STOP, START measure
Only for service purposes
Upon measurement “STOP”, all interfaces (e.g. internal LPM40, I/O module boxes) are
deactivated.
Upon measurement “START”, all interfaces are re-initialized and the measurement
sequence is started.
Settings
Progr. existing I/O
modules
All addresses of existing and active boards of the I/O module boxes are
displayed and can be changed.
Progr. new I/O modules
All addresses of existing and active boards of the I/O module boxes are
displayed and – for new boards – addresses can be added.
For analog input, analog output, and heating controller:
While choosing an address, the read values are displayed (ACTUAL
parameters) as well as recommended default values (NOMINAL parameters).
The nominal parameters can be altered and programmed (programming will
be prompted while leaving the menu).
Possible entry
Meaning
Function
DO
DI
AO
AI
HC
Digital output
Digital input
Analog output
Analog input
Heating controller
Gain
-32768...32767
Default = 0 (K = 1.0)
Offset
-4096...4095
Default = -102
Gain/Offset Correction
ON/OFF
Default = ON
HC mode
H1, T1, B1
1
1
Only for function HC
Default = H1
Write protection
ON/OFF
Default = ON
Search existing
I/O modules
All I/O module boxes are searched and the addresses found are displayed.
You can assign an address to one board at a time, only. All other boards must
be switched to the “not active” condition. There is a corresponding message in
the menu.
For assigning addresses to the boards
→
“I/O Module Box, User's Manual“
Содержание MCS100E
Страница 1: ...O PERATING INSTRU CTIO NS MCS100E IR Analyzer Title Page Commissioning Operation Maintenance...
Страница 10: ...Contents 10 MCS100E Operating Instructions 8009504 VYWA7 V3 1 2018 01 SICK AG...
Страница 98: ...Operation 98 MCS100E Operating Instructions 8009504 VYWA7 V3 1 2018 01 SICK AG Subject to change without notice...
Страница 112: ...Maintenance 112 MCS100E Operating Instructions 8009504 VYWA7 V3 1 2018 01 SICK AG Subject to change without notice...