7
OPERATION
8020065-ZSP4/2017-08-10|SICK
O P E R A T I N G I N S T R U C T I O N S | Master Data Analyzer
Subject to change without notice
82
7.4
Transmitting measurement results
7.4.1.1
Direct data output if the device is connected to a server
If the circle symbol for the connection status lights up green, the device is connected to
the customer server. After the measurement is taken, the measurement results are
automatically transmitted to the customer system by the MSC800 controller via the
defined interface.
The transmitted measured values remain on the display.
7.4.1.2
Saving measurement data internally (only for operating mode with bar code scanning)
If the device is not currently connected to the server, the circle symbol for the connection
status is grayed out. The measurement results cannot be transmitted.
In this case, the measurement results are stored internally on the MSC800. Up to 1000
measurement data sets can be stored.
As soon as the connection is restored, the measurement data are automatically
transferred to the customer server. The transmitted measured values are then deleted
from the temporary memory bank.