Operating Instructions
Laser Measurement Systems of the LMS500 Product Family
Chapter
10
10.2.4
Read scan data
The measured value output is started using this message. It is a prerequisite for this action
that the LMS is in the “Measurement” status. For this purpose the measurement mode
must be started, there are two ways you can undertake this action:
•
start via SOPAS ET
P
ROJECT
TREE
, LMS…, P
ARAMETER
, B
ASIC
PARAMETERS
, area M
EASUREMENT
.
•
section 10.2.1 “Start measurement” on page 77
Single or continuous measured value output
There are two ways of requesting measured value output (see
):
•
Exactly one measured value message can be requested using the
sRN LMDscandata
message — the last scan measured is transferred.
•
Measured data can be continuously requested using the
sEN LMDscandata
message —
measured data are then transferred until the measured value output is stopped using
the
sEN LMDscandata
message.
Request method 1: single measured value output
Message structure:
sRN LMDscandata
Request method 2: continuous measured value output
Message structure:
sEN LMDscandata
MeasurementStartStop
Message structure:
sRA/sSN LMDscandata
VersionNumber DeviceNumber
SerialNumber DeviceStatus MessageCounter ScanCounter
PowerUpDuration TransmissionDuration InputStatus OutputStatus
ReservedByteA ScanningFrequency MeasurementFrequency
NumberEncoders [EncoderPosition EncoderSpeed]
NumberChannels16Bit [MeasuredDataContent ScalingFactor
ScalingOffset StartingAngle AngularStepWidth NumberData
[Data_1 Data_n]] NumberChannels8Bit [MeasuredDataContent
ScalingFactor ScalingOffset StartingAngle AngularStepWidth
[NumberData Data_1 Data_n] Position [XPosition YPosition
ZPosition XRotation YRotation ZRotation RotationType] Name
Message part
Description
Variable type
Length
(byte)
Value range
Type of command
Request (SOPAS read by name)
string
3
sRN
Command
Data request
string
11
LMDscandata
Message syntax VII:
Request “Read scan data”
Message part
Description
Variable type
Length
(byte)
Value range
Type of command
Request (SOPAS event by name)
string
3
sEN
Command
Data request
string
11
LMDscandata
MeasurementStartStop
Enum8
1
0
stop of the measured
value output
1
start of the measured
value output
Message syntax VIII:
Request “Read scan data”