NOTE
If the
Setup
LED lights up yellow or red, the read result is inadequate. If this is
the case, check the alignment and distance of the device in relation to the code.
Repeat the process.
5.
Wait until the
Setup
process has finished. The bar graph display shows the prog‐
ress of the
Setup
function in percent. 100% means the
Setup
has been completed.
✓
The
Setup
LED indicates the result
see "Display and control elements", page 17
.
6.
Exit
Live
mode. Save parameters.
Device saves
the parameters
2
Result |Teach
|Focus
L/A GbE
Funct
Light
O
Ready |Test
Press key 3 seconds
1
0%
100%
|
Setup
1
Press the
p
function button for 3 seconds
2
Device permanently saves the parameters
✓
The existing configuration in the device is overwritten.
Alternatively, the device saves the parameters automatically if 5 minutes elapse without
a pushbutton being pressed, and it returns to read mode.
7.4
Initial commissioning
The device is adjusted to the application using the SOPAS ET configuration software.
The default factory settings of the device are the starting point. The default parameter
values (configuration data) in the working memory of the device can be modified. For
this purpose, you can independently create an application-specific parameter set in
SOPAS ET and change it if required. You then load the current parameter set to the
permanent parameter memory of the device.
NOTE
After completing configuration, permanently save the parameters in the nonvolatile
device memory. As part of a data backup plan, always save the current parameter set
outside the device memory. If necessary (device failure, etc.), this makes it easier to
restore the current parameter set used to date to a replacement device of the same
type,
see "External data back-up", page 55
Memory organization for parameter set
The following diagram shows the memory organization scheme for the internal and
external components involved.
7
COMMISSIONING
54
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
8018071/1E1C/2021-12-16 | SICK
Subject to change without notice