5.4
Adjusting the focus position
5.4.1
Adjusting focus with the focus adjustment tool
Overview
The user adjusts the focus position to suit the required working distance with the help
of the focus adjustment tool. The focus position is valid for one working distance. The
device does not perform automatic tracking (auto focus) if, for example, the working
distance changes significantly. The focus adjustment tool is included with delivery.
Important information
NOTE
Only relevant for product type V2D61xx-x
M
xxxx.
NOTICE
Risk of product damage
If the focus adjustment tool is turned with too much force, the device will be damaged.
■
Observe maximum tightening torque.
Approach
7
1
2
3
5
4
6
8
Figure 13: Manually adjusting the focus position with the help of the focus adjustment tool
1
Red LED = the focus position set
2
Blue LED = current working distance
3
Rotate the focus adjustment tool
4
The red LED (current focus position) is made to approach the blue LED (current working
distance) by turning the focus adjustment tool.
5
Target focus position setting
6
Actual focus position setting
7
Green LED = focus position has been adjusted to suit the working distance (actual status
= target status)
8
Focus position coincides with the working distance (actual status = target status)
1.
Mount and align the device at the required working distance.
2.
Activating the
Focus
device function:
°
Press the function button (
p
) for 3 seconds.
5
MOUNTING
26
O P E R A T I N G I N S T R U C T I O N S | Lector61x
8024830/1FGB/2022-03-29 | SICK