Chapter
5
Operating instructions
LCUR1411
26
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8011281/TF99/2013-02-28
Electrical installation
Under constant pressure and with simultaneous
Gentle pivoting movement away from the terminal, guide screwdriver to the stop,
Insert stripped wire,
Remove screwdriver, the contact is then made.
5.1.2
Configuration of the LCUR1411 to suit the old device to be replaced
Depending on the ESPE to be replaced, wire links need to be fitted to the LCUR1411 to
achieve the correct function. The setting for the wire jumpers is described in the following
tables.
The setting as supplied is wired for LVU206-1406 on terminal 1.2 and 3.2.
Selection 2: terminal assignment on the logic
module
Do not
change
Check and wire to suit the old
device to be replaced
a
b
c
d
c‘
d‘
3.4
1.4
3.3
1.3
3.2
1.2
Old device type
Selection 1:
wire links
(pink)
core colour of the wire links
LVU
200/300
A1,
pk
(G)
G1
gr
wh
Not permitted! pk (C)
pk (D)
450-1400
G2
206-1406
G3
LVS
300-1600
G4
pk (C)
pk (D)
Not permitted!
AGS
G5
Colour coding:
gr = grey, wh = white, pk (C) = pink with Clip C, pk (D) = pink with Clip D,
pk (G) = pink with Clip G
Selection 1
: Starting from terminal A1 as per the table, lay the pink wire link to a terminal
between G1 and G5 depending on the old device. As supplied the link is connected for
LVU206-1406 from A1 to G3.
Fig.11: Using the spring
terminals
Note
Tab.3: Setting for the wire
jumpers in the LCUR1411 to
suit the old device to be
replaced