Operating Instructions
ISD 230/260/280 IR Data Transmission Systems
Chapter
5
© SICK AG · Auto Ident · Germany · All rights reserved
8 008 207/30-11-2001
26
Electrical installation
5.1.4
Connector pin assignment
All interfaces are routed via a 9-pin D Sub connector.
Pin
Functions
CL 20 mA, RS 422,
RS 485 (2-wire)
RS 232
interfaces
RS 485 (4-wire)
1
1)
+24 V DC
-
-
-
2
“Contamination“
-
-
-
switching output
2)
3
“Light path free“
-
-
-
switching output
2)
4
“Transmitter off“
-
-
-
switching input
5
1)
GND/ 0 V
GND/ 0 V
GND/ 0 V
GND/ 0 V
6
-
R+
3)
R+/T+
3)
or B
4)
RxD
7
-
R–
3)
R–/T–
3)
or A
4)
-
8
-
T+
-
TxD
9
-
T–
-
-
1) Wire cross-section for devices with integrated heater: min. 0.75 mm
2
at a maximum cable length of 20 m
2) PNP technology
3) With connectable line termination (
Chapter 5.1.6
Connecting the data interface
,
Line termination (RS 422/485)
, Page 30
)
4) A and B apply to Profibus and Profibus-DP
Tab.
5-3: ISD 230: Pin assignment of the 9-pin D-Sub connector
5
1
9
6
9-pin
D Sub connector
Ø
Wire all the connections with a minimum wire cross-section of 0,15 mm
2
(cooper wire)!
5.1.5
Preparations for electrical installation
Requirements for the data interface
Table 5-4
shows the recommended maximum cable lengths as a function of the data
transfer rate.
Interface type
Transfer rate
Distance to the host
CL 20 mA
max. 9,600 Bd
max. 1,000 m
RS-232
bis 19,200 Bd
max. 10 m
RS-422/485
1)
max. 38,400 Bd
max. 1,200 m
1) with suitable line termination
Tab.
5-4: ISD 230: Maximum cables lenghts between the ISD and the host
Ø
In order to prevent interferences, do not lay the cable parallel to power supply and
motor cables (for example in cable dust) for a longer stretch.
Supply voltage
The ISD 230 system requires a supply voltage of 24 V DC ±20 % in accordance with IEC
742 (functional extra-low voltage). The continuous current consumption per unit is max.
0.4 A (without heater).
The SICK AMS 50-013/-012 connection module with integrated power pack or any other
power supply unit that supplies a voltage of 24 V DC in accordance with IEC 742 can be
used as a power supply.
Configuration
and
electrical
installation
of
the
ISD
230