5.3.2
Attaching the warning label
Devices and illuminations (VI55I) with LEDs in risk group RG 2 feature the following
warning label.
Figure 3: Risk Group 2: CAUTION - Possibly hazardous optical radiation emitted from this product.
Do not look into the lamp during operation. This could damage your eyes. ICE 62471:2006-07;
EN62471:2008-09
The warning label is located on the exterior of the housing of the devices. For the
illumination units, the warning label is located on the outer ring.
Integrable illumination unit types in risk group RG 2 that are to be mounted by the
user are accompanied by an additional black and yellow warning label for RG 2 optical
radiation.
Attach the additional warning label to the outside of the protective optics cover in a
clearly visible location. When the protective optics cover is mounted, the warning label
on the illumination unit is hidden.
1.
Affix the illumination unit to the device housing.
2.
Manually adjust the sharpness and mask settings of the lens unit and check using
the live image in SICK AppStudio.
3.
Attach the protective optics cover and screw it tight.
4.
Attach the warning label to the protective optics cover near the light outlet so that
it is clearly visible.
5.
If the device itself is integrated into machinery, for example, in a way which
obscures the warning label attached, additional, clearly visible labels should be
attached to the machinery close to where the light is emitted.
For commissioning using SICK AppStudio
see "Installing SensorApps and programming
.
5.4
Mounting location
5.4.1
Work area
Depending on the device type, the working range is between 50 mm and 2,200 mm.
•
Dynamic Focus device variant: the device automatically adjusts its focus position
to the working distance with
Auto-Setup
.
•
Flex device variant: the focus position is manually set on the lens.
The field of view is determined by the focus position, the focal length of the lens, and
the working distance. The necessary working distance can be determined from the field
of view diagram,
see "Field of view diagrams", page 27
.
5.4.2
Mounting bracket and reflection prevention
In order to avoid reflections from the surfaces to be scanned, mount the device so that
it is tilted from the perpendicular to the surface.
MOUNTING
5
8019946/1EJ6/2022-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP63x Flex C-mount and S-mount
25