4
INSTALLATION
16
Operating Instructions | InspectorP Rack Fine Positioning
8024534 / 16UW / 2020-02-26
Subject to change without notice
The card slot for the microSD memory card is located at the top of the device at the
rear under the hinged cover.
1.
Switch off the supply voltage to the device.
2.
Undo the screws on the hinged cover.
3.
Open the cover.
4.
Insert the microSD memory card.
5.
Close the hinged cover. Make sure that the cover is completely flush with the
housing.
6.
Tighten the screws on the hinged cover again.
7.
Switch on the supply voltage for the device.
8.
In the SICK AppManager, in the
Device
window, click on the
Clone
button.
From now on, the device will back up the current parameter set on the
microSD memory card.
4.1.4
Installing firmware updates
To install firmware updates using SICK AppManager:
1.
Pull the file with the firmware update into the
Firmware
window with drag and
drop.
2.
Select the file you want to install.
3.
Click on the
Install
button in the lower right section of the window to install the
update.
4.2
Mounting
4.2.1
Mounting requirements
General mounting requirements
•
Distance from the device to the positioning mark (hole or reflector):
100 mm … 1,995 mm. The distance depends on the device type and type of
positioning mark.
•
The user can locate the positioning mark anywhere in the field of view of the device
to suit the application situation. Recommendation: Locate the positioning mark at
the center point of the image.
•
The positioning mark must be within the area that is visible to the device in single
and double deep applications when mounted at a permissible working distance.
•
An algorithm is available to classify and ignore multiple positioning marks within the
field of view of the device.
Mounting requirements: holes as positioning marks
•
Ensure that no objects or contamination with distinct contours, or with a similar
diameter or surface as the hole are present in the field of view.
•
Ensure that there are no light sources mounted behind the hole.
•
Ensure that the beams of the high-bay rack system are not heavily contaminated in
the area of the hole. If necessary, clean the area around the hole.