Operating instructions
Chapter
6
ICR 84x Image Code Reader
Operation
8 010 961/0000/10-05-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-23
Parameterize reading trigger:
two external sensors
–
or
–
Ö
D
EVICE
CONFIGURATION
tab
Ö
S
ENSOR
1 section
– Debouncing
– Invert Input (if necessary)
Ö
R
EADING
T
RIGGER
P
ARAMETERS
button
Start (sensor 1):
Ö
S
TART
OF
READING
INTERVAL
section
– Sensor Input
Ö
S
TART
DELAY
section
– Time controlled: value
Ö
D
ELAY
CONTROLLING
section
– Time controlled delaying
Ö
F
IRST
T
RIGGER
S
ENSOR
section
– Edge
or
– Level
Stop (sensor 2):
Ö
E
ND
OF
R
EADING
I
NTERVAL
section (No Read)
– Trigger source
Ö
D
EVICE
CONFIGURATION
tab
Ö
S
ENSOR
2 section
– Assignment
– Reading trigger stop
– Debouncing: value
– Invert Input (if necessary)
Output of reading result referred to beginning of reading
interval:
Ö
R
ESULT
OUTPUT
section (Good Read)
– End of reading interval
or
– Immediate output
or
– End of next reading interval
Note:
Connect external sensor 1 (start) to "Sensor 1" switching input
and sensor 2 (stop) to "Sensor 2" switching input!
Action
Settings in CLV Setup
Table 6-2: Guide: Parameterizing the reading trigger and output of reading result (contd.)