Chapter
9
Operating instructions
ICR 84x Image Code Reader
9-2
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 961/0000/10-05-2005
Technical data
9.1.1
Suitable bar code lengths in the reading area
Switching outputs
2 (“Result 1“, “Result 2“)
– Variable output function for result status
– Variable pulse duration (static, 10 to 990 ms)
– “Result 1“: low side switch, additional function: trigger or direct powering of an external
field illumination, NPN, I
omax
= 100 mA, short-circuit-proof
– “Result 2“: high side switch, PNP, I
omax
= 100 mA, short-circuit-proof
Electrical connection
15-pin D-Sub HD connector, cable length 0.9 m (2.95 ft)
Ethernet connection: RJ 45 socket 10baseT
Operating voltage/power consumption
15 to 30 V DC pursuant to IEC 364-4-41/ typ. 7 W (290 mA at 24 V DC), max. 10 W
Housing
Zinc die-cast, does not represent a problem in paint shops
Enclosure rating
Device IP 65 (pursuant to DIN 40 050), Ethernet connection IP 30 when connected
Protection class
Class 3 (pursuant to VDE 0106/IEC 1010-1)
EMC/ vibration / shock tested
According to EN 61000-6-2, EN 61000-6-4/ to EN 61010-1/ to EN 60068-2-27
Weight
Approx. 900 g (31.75 oz) with connection cable
Operating/storage temperature
0 to +40
°
C/ –20 to +70
°
C (+32 to +104
°
F/–4 to +158
°
F)
Max. rel. humidity
90 %, non-condensing
Colour
SICK blue (RAL 5012)
1)
(Default setting); in Reading mode with the “Switching input sensor “ and “Serial interface“ pulse types
2)
Reading interval: time window generated internally for evaluating the code
3)
Standard decoder for bar codes: also Pharmacode and RSS
4)
SMART decoder for bar codes: Code 39: max. 30 characters; Codebar: max. 30 characters; Code 128, EAN 128: max. 48 characters (max. 96 “half characters“)
Type
ICR 840 (Standard)
Table 9-1: Technical specifications of ICR 84x (contd.)
Bar code type
Module width
Number of characters
Length incl. quiet zone
Code 128
0,15 mm (5.9 mil)
18
38 mm (1.49 in)
0,25 mm (9.8 mil)
9
39 mm (1.53 in)
0,35 mm (13.8 mil)
5
39 mm (1.53 in)
Code 39
0,15 mm (5.9 mil)
16
38 mm (1.49 in)
0,25 mm (9.8 mil)
8
37 mm (1.45 in)
0,35 mm (13.8 mil)
5
39 mm (1.53 in)
2/5 Interleaved
0,15 mm (5.9 mil)
32
38 mm (1.49 in)
0,25 mm (9.8 mil)
18
39 mm (1.53 in)
0,35 mm (13.8 mil)
12
39 mm (1.53 in)
Table 9-2: Suitable bar code lengths at focus position (distance 80 mm (3.15 in), reading area