Chapter
6
Operating instructions
ICR 84x Image Code Reader
6-46
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 961/0000/10-05-2005
Operation
6.6.2
Error messages
Error messages indicate the following types of error:
•
a device defect
•
incorrect parameter settings
•
errors during data transmission to the host
lists the messages with the associated corrective measures.
Note
To call up the most recent error to occur in the CLV, enter command "2?SF" in the command
line of the terminal emulator.
6.7
Switching the ICR off
1.
If the parameter set was modified in CLV Setup or was only stored temporarily in ICR
via a download (“Temporary“ option or via context menu (right mouse button)), the
parameter set must be stored permanently in the ICR by choosing the P
ERMANENT
storage option.
2.
Save parameter set as a “*.scl“ configuration file in CLV Setup.
3.
Switch off the power supply of the CDB 420 or CDM 420 or pull the plug of the ICR from
the connection module.
The last parameter set stored permanently in the ICR remains valid.
Archiving the parameter set:
We recommend that you print out the configuration file in order to archive the parameter set.
1.
Click
in the toolbar.
The P
RINT
F
ILE
dialog box is then displayed.
2.
Enter a comment in the input field to assign the printout to the ICR.
Confirm the dialog box with “OK“.
The P
RINT
dialog box for configuring the printer is then displayed.
3.
Edit the dialog box accordingly and confirm.
CLV Setup prints out the current configuration file in the form of a table.