8
Technical data
8.1
Technical data
Table 4: Features
Features
Variant with cable entry
Housing material
Fiberglass-reinforced polyester
Enclosure rating (IEC 60529)
IP 65
Mechanical service life
1 × 10
6
B
10d
(EN ISO 13849)
2 × 10
6
Switching operation with small load
Type
Type 2 (EN ISO 14119)
Coding level of the actuator
Low coding level (EN ISO 14119)
Ambient operating temperature
–20 °C … +60 °C
Connection type
3 × M20
Max. actuation speed
9.6 m × min
–1
Max. actuation frequency
3,600 × h
–1
Pollution degree
(external, according to EN 60947)
3 × (industry)
Max. force against which unlocking is possible 50 N
Max. retaining force, unlocked
30 N
Locking force F
max
Mounting with plastic locating pins
Mounting with metal bolts
1,950 N
2,600 N
Locking force F
Zh
according to (EN ISO 14119)
(F
Zh
= F
max
/1.3)
Mounting with plastic locating pins
Mounting with metal bolts
1,500 N
2,000 N
Minimum door radii
Table 5: Electrical data
Electrical data
Thermal current l
th
10 A
Switching principle
Slow action switching element
Wire cross-section, (rigid/flexible)
0.34 mm
2
... 1.5 mm
2
Rated insulation voltage U
i
250 V
Rated impulse withstand voltage U
imp
2.5 kV
Utilization category (IEC 60947-5-1)
AC-15: 230 V, 3 A; DC-13: 24 V, 3 A
Min. switching voltage
1)
5 V
Min. switching current at 24 V DC
5 mA
Short-circuit protection (control fuse) (IEC
60269)
6 A gG
Solenoid supply voltage (+10% … –15%)
AC/DC 24 V
Max. solenoid power
7 W
ED switch-on time
100%
1)
At 10 mA.
8
TECHNICAL DATA
20
O P E R A T I N G I N S T R U C T I O N S | i200 Lock
8020558//2017-02-14 | SICK
Subject to change without notice