11
Technical specifications
HTB18
HTB18-
xxxxxxD02
HTB-xxxxxxD04 HTB18-M / -L /-
U
HTB18L
Laser class
1
Sensing range
5 ... 150 mm
5 ... 50 mm
5 ... 100 mm
5 ... 150 mm
30 ... 250 mm
Sensing range max.
5 ... 300 mm
1)
5 ... 50 mm
1)
5 ... 100 mm
1)
5 ... 300 mm
1)
30 ... 300 mm
1)
Light spot diameter/distance
7 mm / 300
mm
6.5 mm / 50
mm
6.25 mm / 100
mm
7 mm / 300
mm
2 mm/ 120 mm
Supply voltage V
S
DC 10 ... 30 V
2)
DC 10 ... 30 V
2)
DC 10 ... 30 V
2)
AC 90 ... 250
V
3)
DC 10 ... 30 V
2)
Output current I
max.
≤ 100 mA
≤ 100 mA
≤ 100 mA
Communication mode
COM2
COM2
COM2
COM2
IO-Link
1.1
1.1
1.1
1.1
Max. switching frequency
1,000 Hz
4)
1,000 Hz
4)
1,000 Hz
4)
1,000 Hz
4)
1,000 mA
4)
Max. response time
≤ 0.5 ms
5)
≤ 0.5 ms
5)
≤ 0.5 ms
5)
≤ 0.5 ms
5)
≤ 0.5 ms
5)
Enclosure rating
IP67, IP69
6)
IP67, IP69
6)
IP67, IP69
6)
IP67, IP69
6)
IP67, IP69
6)
Protection class
III
III
III
II
7)
III
Circuit protection
A, B, D
8)
A, B, D
8)
A, B, D
8)
A, B, D
8)
A, B, D
8)
Ambient operating temperature
-40 ... +65 °C
-40 ... +65 °C
-40 ... +65 °C
-40 ... +70 °C
-10 ... +55 °C
1)
We recommend using compound triangular reflectors or reflective tape to ensure reliable operation. Suitable reflectors and foils can be
found in the SICK accessories range. Use of reflectors with large-scale triple structures can negatively influence functionality.
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
ss
3)
Limit values
4)
With light / dark ratio 1:1, deviating values possible with IO Link
5)
Usage category: AC-15, DC-13 (EN 60947-1)
5)
Signal transit time with resistive load
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
Rated voltage AC/DC 250 V, overvoltage category II
8)
valid for Q\ on Pin2, if configured with software
8)
A = U
V
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
9)
Reference voltage DC 50 V
11
TECHNICAL SPECIFICATIONS
22
8017850.1A15 / 2020-12-14 | SICK
Subject to change without notice
Содержание HTB18
Страница 1: ...O P E R A T I N G I N S T R U C T I O N HTB18 L Hybrid photoelectric sensors...
Страница 27: ...B E T R I E B S A N L E I T U N G HTB18 L Hybrid Lichtschranken de en es fr it ja pt ru zh...
Страница 52: ...N O T I C E D I N S T R U C T I O N HTB18 L Capteurs photo lectriques hybrides de en es fr it ja pt ru zh...
Страница 78: ...I S T R U Z I O N I P E R L U S O HTB18 L Sensori fotoelettrici ibridi de en es fr it ja pt ru zh...
Страница 104: ...I N S T R U C C I O N E S D E U S O HTB18 L Fotoc lulas h bridas de en es fr it ja pt ru zh...
Страница 130: ...M A N U A L D E I N S T R U E S HTB18 L Barreiras de luz h bridas de en es fr it ja pt ru zh...
Страница 156: ...HTB18 L de en es fr it ja pt ru zh...
Страница 180: ...HTB18 L de en es fr it ja pt ru zh...
Страница 199: ...LED LED 84 2 LED 84 2 86 WEEE 87 SICK 86 8017850 1A15 2020 12 14 SICK Subject to change without notice 199...
Страница 205: ...HTB18 L de en es fr it ja pt ru zh...
Страница 209: ...92 2 3 2 3 4 1 1 2 3 4 93 SICK 0 56 49 92 8017850 1A15 2020 12 14 SICK Subject to change without notice 209...
Страница 222: ...y x 53 95 3 270 270 54 C 95 222 8017850 1A15 2020 12 14 SICK Subject to change without notice...
Страница 225: ...C 95 2 97 WEEE 98 SICK 97 8017850 1A15 2020 12 14 SICK Subject to change without notice 225...