8
Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 5: Troubleshooting
LED/fault pattern
Cause
Measures
Yellow LED does not light up
even though the light beam is
aligned to the object and the
object is within the set sensing
range
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Voltage interruptions
Ensure there is a stable power
supply without interruptions
Sensor is faulty
If the power supply is OK,
replace the sensor
Yellow LED lights up, no object
in the path of the beam
The sensing range distance is
too large
Reduce the sensing range,
see Figures 6-8 and
Object is in the path of the
beam, yellow LED does not
light up
Distance between the sensor
and the object is too long or
sensing range is set too short
Increase the sensing range,
see Figures 6-8 and
9
Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
10
Maintenance
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
•
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
•
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
8
TROUBLESHOOTING
10
O P E R A T I N G I N S T R U C T I O N | GTB2 Flat
8023328.1C14/2021-06-28 | SICK
Subject to change without notice
en
Содержание GTB2F-X 11 Series
Страница 13: ...I N S T R U C C I O N E S D E U S O GTB2 Flat Fotocélulas miniatura de en es fr it ja pl pt ru zh ...
Страница 37: ...B E T R I E B S A N L E I T U N G GTB2 Flat Miniatur Lichtschranke de en es fr it ja pl pt ru zh ...
Страница 49: ...I S T R U Z I O N I P E R L U S O GTB2 Flat Sensori fotoelettrici miniaturizzati de en es fr it ja pl pt ru zh ...
Страница 61: ...取 扱 説 明 書 GTB2 Flat 超小型光電センサ de en es fr it ja pl pt ru zh ...
Страница 72: ...I N S T R U K C J A E K S P L O A T A C J I GTB2 Flat Fotoprzekaźniki Mini de en es fr it ja pl pt ru zh ...
Страница 84: ...M A N U A L D E I N S T R U Ç Õ E S GTB2 Flat Barreiras de luz miniatura de en es fr it ja pl pt ru zh ...
Страница 108: ...操 作 指 南 GTB2 Flat 微型光电传感器 de en es fr it ja pl pt ru zh ...