7.1
Troubleshooting table
Table 5: Troubleshooting
LED indicator/fault pattern
Cause
Measures
Green LED does not light up
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Green LED does not light up
Voltage interruptions
Ensure there is a stable power
supply without interruptions
Green LED does not light up
Sensor is faulty
If the power supply is OK,
replace the sensor
Yellow LED flashes
Sensor is still ready for opera‐
tion, but the operating condi‐
tions are not ideal
Check the operating condi‐
tions: Fully align the beam of
light (light spot) with the
object / Clean the optical sur‐
faces / Readjust the sensitiv‐
ity (potentiometer) / Check
sensing range and adjust if
necessary,
Yellow LED lights up, no object
in the path of the beam
Distance between the sensor
and the background is too
short
Reduce the sensing range,
Object is in the path of the
beam, yellow LED does not
light up
Distance between the sensor
and the object is too long or
sensing range is set too short
increase the sensing range,
take note of the distance
between the sensor and the
background,
8
Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document, indi‐
cates that a product is subject to these regulations.
9
Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
TROUBLESHOOTING
7
8021184.16B5 | SICK
Subject to change without notice
11
Содержание GRTB18SV
Страница 14: ...B E T R I E B S A N L E I T U N G GRTB18 S V Rundlichtschranken de en es fr it ja pt ru zh...
Страница 38: ...M A N U A L D E I N S T R U E S GRTB18 S V Barreira de luz cil ndrica de en es fr it ja pt ru zh...
Страница 50: ...I S T R U Z I O N I P E R L U S O GRTB18 S V Sensore fotoelettrico cilindrico de en es fr it ja pt ru zh...
Страница 62: ...I N S T R U C C I O N E S D E U S O GRTB18 S V Sensores fotoel ctricos cil ndricos de en es fr it ja pt ru zh...
Страница 74: ...GRTB18 S V de en es fr it ja pt ru zh...
Страница 82: ...34 84 67 67 1 35 LED LED LED LED 67 82 8021184 16B5 SICK Subject to change without notice...
Страница 83: ...LED LED 82 81 LED 82 LED 82 68 WEEE 69 SICK 68 8021184 16B5 SICK Subject to change without notice 83...
Страница 85: ...GRTB18 S V de en es fr it ja pt ru zh...
Страница 93: ...39 96 77 77 1 40 LED LED 77 8021184 16B5 SICK Subject to change without notice 93...
Страница 94: ...LED LED LED LED 94 92 LED 94 LED 94 78 WEEE 79 SICK 78 94 8021184 16B5 SICK Subject to change without notice...
Страница 96: ...GRTB18 S V de en es fr it ja pt ru zh...
Страница 104: ...270 44 43 44 108 87 87 104 8021184 16B5 SICK Subject to change without notice...
Страница 105: ...87 1 45 C 106 103 106 106 88 WEEE 87 8021184 16B5 SICK Subject to change without notice 105...
Страница 106: ...89 SICK 89 106 8021184 16B5 SICK Subject to change without notice...