NOTE
The user must not make any changes to the element settings.
7.3.3
Configuring speed limits
1.
Move the mouse cursor to the
Logic editor
button.
2.
Click on
K110-2 / MOC1 - Logic editor
.
3.
Select the
Position_Monitor
logic page.
✓
The view opens. The
Position_Monitor
page appears.
Figure 6: Position_Monitor page view
Position ranges can be set and monitored on this page. The two sensors provide sepa‐
rate status signals.
This page is protected with a password. Configurations must be set in the
Position Moni‐
tor
function block.
1.
Move the mouse cursor to the
Position Monitor
function block.
2.
Double-click on the function block.
✓
The view opens. The window containing the settings for the function block will
appear.
Figure 7: Settings window for Position Monitor function block
CONFIGURATION
7
8020941/12O9/2019-08-05 | SICK
O P E R A T I N G I N S T R U C T I O N S | Safe Linear Positioning
37
Subject to change without notice